Demonstration of Intermitttent On/Off Aeration at a Municipal Wastewater Treatment Plant for Denitrification and Energy Savings

Final Report

Summary

  1. The intermittent on/off aeration did not affect the effluent BOD5 and TSS concentration. The sludge settleabllity was also not affected. As a result, electricity cost for aeration could be reduced by approximately 30% by shutting off the jet aerators for 8 hours every day in the Ashland WWTP.
  2. By shutting off the jet aerators for 8 hours, nitrate concentrations were below 5 mg-N/L, compared with to 25 mg-N/L without intermittent on/off aeration.
  3. Biological phosphorus removal to 1 mg/L was not achieved by the intermittent on/off aeration even though PAOs seem to be developed in the ditch. More work needs to be done to investigate the PAO existence and its behavior in the activated sludge with an intermittent aeration.

 