Demonstration of Intermitttent On/Off Aeration at a
Municipal Wastewater Treatment Plant for
Denitrification and Energy Savings
Final Report
Intermittent On/Off Aeration
Effluent Quality of Ashland WWTP
Before and After On/Off Intermittent Aeration
The operation and performance of the intermittent on/off aeration were compared to the
continuous aeration. Figure 3.2 shows the effluent BOD5
and TSS concentrations before and after intermittent on/off operation. The results
indicated that the effluent BOD5 concentration was
slightly increased during the beginning of intermittent aeration; however, it was still
under the limit of 30 mg/L. The TSS concentration were not affected by the intermittent
aeration. The sludge settleability expressed by sludge volume index (SVI) was also not
affected by the on/off intermittent operation (Figure 3.3). Updated results have indicated
that there was no apparent difference in effluent BOD5,
TSS concentrations and sludge settleability at the Ashland WWTP during the operation of
intermittent aeration.